Cmpe125u5b



  1. Ducane Cmpe125u5b Troubleshooting
  2. Ducane Furnace Model Cmpe125u5b Specs Chart
  3. Ducane Cmpe125u5b
  4. Cmpe125u5b Manual
As the title states, we have a Ducane CMPE125U5B gas furnace that came with the house. I suspect that the blower motor is starting to go and would like to order a replacement to have on hand.
Unfortunately, without pulling the unit, I do not have a part number as there was no manual here to go with the furnace.
I have spent hours over the past 2 days scouring the internet for a copy, a parts list, or any kind of confirmation. I have come up empty.
Local HVAC supply store said their vendors don't have direct replacement, but can get a motor of the same horsepower. I'd prefer to have something meant for the unit on hand if possible.
Only specs I can find are:
3/4 Horsepower
12x12 blade
Does anybody know where I might find the info I need?
  • Installation and servicing instructions and user's information manual.installer — affix this instruction packet adjacent to the furnace.homeowner — retain these instructions for future reference.
  • View and Download Ducane CMP A Series installation instructions manual online. CMP A Series furnace pdf manual download.
Loading...

We list Ducane furnace and air conditioning replacement parts that we stock. If you need a part that is not shown below, please call us with your model and serial number and we will see if the.

FEATURES

92.1% AFUE

Heating input range 50,000 – 125,000 BTUH Cooling capacity supported 1 1/2 - 5 ton Upflow/horizontal-left application flexibility Electronic air cleaner connection (115V) Humidifier connection (115V)

5 amp fused low voltage circuit protection

Time delay off for air conditioner SEER enhancement Twinning compatible

WARRANTY

Limited lifetime warranty on heat exchanger, 5-year limited warranty on covered components (see warranty certificate for details)

HEAT EXCHANGER ASSEMBLY

Crimp-TiteTMcrimped aluminized steel primary heat exchanger for longer life and safe operation

Stainless steel secondary heat exchanger maximizes durability and efficiency

VENTING

Category IV appliance

Can be vented horizontally or vertically using 2” or 3” Schedule 40 PVC, ABS, or CPVC (see installation manual for details)

Approved for 2-pipe (direct vent) or single-pipe applications Approved for installations with listed concentric vent kit

CONTROLS

Integrated furnace control with LED diagnostics for fast, accurate troubleshooting

SAFETY

CSA certified for US and Canada

Safety limit prevents overheating

Cmpe125u5b

CABINET

Heavy-gauge, insulated cabinet provides strength and quiet comfort Ducane diagnostic sleeve for fast, safe troubleshooting

INDOOR AIR BLOWER

Three-speed PSC blower motor

D u c a n e G a s F u r n a c e

FITS-ALL 92

Cmpe125u5b

UPFLOW/ HORIZONTAL-LEFT MODELS

Ducane Cmpe125u5b Troubleshooting

Parts

Ducane Furnace Model Cmpe125u5b Specs Chart

T H E D I F F E R E N C E I S Q U A L I T Y.

W W W. D U C A N E H V A C . C O M

D u c a n e G a s F u r n a c e

Cmpe125u5b

FITS-ALL 92

Ducane Cmpe125u5b

UNIT SPECIFICATIONS

CMPE050U2B

CMPE050U3B

CMPE075U2B

CMPE075U3B

GAS

NATURAL (LP WITH CONVERSION KIT)

INPUT RATE (BTU per Hour)

50,000

50,000

75,000

75,000

HEATING CAPACITY

46,000

70,000

AFUE (ISOLATED COMB. SYSTEM)

92.1%

TEMPERATURE RISE

40–70˚F

35–65˚F

45–75˚F

40–70˚F

VOLTS/PHASE/HERTZ

115/1/60

STATIC PRESSURE (certified max)

0.50'W.C.

.

BLOWER MOTOR HORSEPOWER

1/4

1/3

1/4

1/3

BLOWER WHEEL SIZE (dia x width)

10 x 6

NUMBER OF HEAT EXCHANGERS

2

3

FLUE AND AIR INLET PIPE–CONNECTION

2'

(schedule 40 PVC, ABS or CPVC used on all)

LIMIT CONTROL, SNAP DISC STYLE

170˚F

170˚F

170˚F

170˚F

GAS VALVE/IGNITION CONTROL

INTEGRATED FURNACE CONTROL W/ 115V HSI SYSTEM

TRANSFORMER

40 VA. 115 VAC PRIMARY, 24 VAC SECONDARY, FOOT-MOUNTED

MAXIMUM OUTLET TEMPERATURE

180˚F

SHIPPING WEIGHTS

152

158

CMPE100U3B

CMPE100U4B

CMPE125U5B

GAS

NATURAL (LP WITH CONVERSION KIT)

INPUT RATE (BTU per Hour)

100,000

100,000

125,000

HEATING CAPACITY

93,000

116,000

AFUE (ISOLATED COMB. SYSTEM)

92.1%

TEMPERATURE RISE

40–70˚F

45–75˚F

VOLTS/PHASE/HERTZ

115/1/60

STATIC PRESSURE (certified max)

0.50'W.C.

BLOWER MOTOR HORSEPOWER

1/3

1/2

3/4

BLOWER WHEEL SIZE (dia x width)

10 x 9

12 x 9

12 x 12

NUMBER OF HEAT EXCHANGERS

4

5

FLUE AND AIR INLET PIPE–CONNECTION

2'

(schedule 40 PVC, ABS or CPVC used on all)

LIMIT CONTROL, SNAP DISC STYLE

170˚F

170˚F

GAS VALVE/IGNITION CONTROL

INTEGRATED FURNACE CONTROL W/ 115V HSI SYSTEM

TRANSFORMER

40 VA. 115 VAC PRIMARY, 24 VAC SECONDARY, FOOT-MOUNTED

MAXIMUM OUTLET TEMPERATURE

180˚F

SHIPPING WEIGHTS

187

217

Cmpe125u5b Manual

NOTES: U=Upflow (CMPE050U3)